Overview

Basic Info.

Model NO.
GC2019
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Polychromator
Certification
ISO9001, CE
Customized
Customized
Transport Package
Vacuum, Moistureproof in Wooden Case
Specification
180mm
Trademark
Caidao
Origin
China
HS Code
9031809090
Production Capacity
1000PCS/Year

Product Description

Product Description
GC2019 System Capabilities

 Multi channels design supports two inlets and five detectors
 Full range digital data output enables the smallest and largest peaks to be quantitated in a single run
 7"touch screen
 Embedded uniLite system in front panel, allow user to edit method, sequence directly
 User can run the samples even the CDS is offline. All data would be stored in
GC.
 Web-browser based user interface, including real time plot
 Full EPC is available for all inlets and detectors
 Control range and resolution are optimized for the specific inlet or detector module
 EPC with capillary columns provides four column flow control modes: constant pressure, ramped pressure (3 ramps), constant flow, or ramped flow (3 ramps)
 Column average linear velocity is calculated


 Atmospheric pressure and temperature compensation is standard, so results do not change, even when the laboratory environment does
 Automatic Liquid Sampling is fully integrated into mainframe control
 Set point and automation control can be done from the local keyboard or via a networked data system

Configuration Options


 Wide selection of inlets
 Split/splitless (S/SL) capillary
 Packed purged injection port (PPIP)
 *Programmable temperature vaporizing (PTV, 3rd party)
 Volatiles interface (VI)
 Temperature-programmable pre-column Endlessly Configurable with:  22 and 150 vials automatic liquid sampler
 3rd  party headspace sampler
 3rd  party Purge and trap
 Gas and liquid sampling valves
 Ambient air sampler and pre-concentrator
 Thermal desorber

 
Application

The product integrates the functions of instrument tuning, data processing, and data analysis to improve the operational performance of the instrument and make research work more efficient.
Food safety: pesticide residues, flavors, fragrances, additives, packaging materials
Environmental monitoring: air, water quality, soil, solid waste.
Industrial manufacturing: textiles, cosmetics, electrical and electronic products, plastic products, biomedicine.
Petrochemical: refinery, chemical plant.
Public security system: criminal investigation, explosives, drugs, physical evidence identification. 

Product Parameters

Oven Dimensions: 28 ×
31 × 16 cm
Accommodates up to two 105 m × 0.530 mm id capillary
columns or two 10-ft glass
packed columns (9 in coil diameter, 1/4 in od), or two
20-ft stainless steel packed columns (1/8 in od)



Operating temperature
range
Ambient temperature +4 °C to 400 °C
-With LN cryogenic cooling:-80 to 450°C.
-With CO2 cryogenic cooling:-40 to 450ºC .
Temperature setpoint resolution:0.1ºC .
 


Temperature Ramps
Supports 30 oven ramps with 31 plateaus. Negative ramps are allowed.
Oven cool down (22°C ambient) 450 to 50 ºC in 4.0 min.
Maximum achievable
temperature ramp rate
120 °C/min
Maximum run time 999.99 min (16.7 h)
Valve Support Support for up to 8 valves.
Independent heated
zones
Not including oven: 12 (two inlets, five detectors, and
five auxiliary)















Electronic Pneumatics
Control (EPC)
• Atmospheric pressure compensation sensor to compensate for altitude and ambient temperature variation is standard.
Pressure may be adjusted by increments of 0.001 psi.
Pressure/Flow ramps: Three maximum.
• Carrier and makeup gas settings selectable for He, H2, N2, and argon/methane.
• Flow or pressure setpoints for each inlet or detector parameter with on both 7"touch screen and the uniStation
• Automated carrier has constant flow, when capillary column dimensions are entered into the GC.
Split/Splitless, inlets have flow sensors for the control of split ratio.
Inlet modules Pressure sensors: Accuracy:
<±2% full="" sca="">le, Repeatability:
<±0.05 psi="">Temperature coefficient
: <±0.<>01 psi/°C, Drift:
<±0.1>psi/6 months.
Flow sensors: Accuracy: <±5%<>
depending on carrier gas,
Repeatability: <<>±0.35% of setpoint,
Temperature coefficient :
<<>±0.20 mL/min normalized temperature
and pressure (NTP)*
  per °C for He or H2;
<<>±0.05 mL/min NTP per °C for
N2 or Ar/CH4.
Detector modules
Accuracy: <±3 ml="">r
7% of setpoint, Repeatability:
<±0.35% of="" setpoint="">nt: <±0.20<> mL/min NTP per °C




Inlets
• Maximum of two inlets installed.
Inlets available:
- Packed purged injection port (PPIP)
- Split/Splitless capillary inlet (S/SL)
- Temperature-programmable cool on-column (PCOC)
- *Programmable temperature vaporizer (PTV, 3rd party)
- Volatiles inlet (VI)













S/SL
• Suitable for all capillary columns.
Split ratios up to 7500:1 to avoid column overload.
• Splitless mode for trace analysis. Pressure-pulsed splitless is
easily accessible for best performance.
Maximum temperature: 400 °C.
EPC available in two pressure ranges: 0- 100 psig (0 to
680 kPa) for best control for columns 0.200 mm diameter; 0-
150 psig for columns <0.200 mm="" diameter.="" pressure="" set=""> point resolution is 0.01 psig. Total flow control/ sensing up to
1000 mL/min (He, H2).
• Gas saver mode to reduce gas consumption without compromising performance.
independent septum purge control(pressure) to eliminate"ghost"peaks and save purge gas when pressure is high.
Total flow setting range:
0 to 200 mL/min N2
0 to 1,000 mL/min H2 or He
PPIP Direct injection onto packed and wide-bore capillary columns. Electronic flow/pressure control:0 to 100 psig
 
  pressure range, 0.0 to 200.0 mL/min flow range.Ranges are chosen to provide optimum per-formance over normal packed column setpoint ranges.
Electronic septum purge flow con-trol.
400°C maximum operating temperature.
Adapters included for 1/4-in.and 1/8-in.packed columns,and 0.530-mm capillary columns.












COC
· Direct injection onto cool capillary column ensures quantitative sample transfer with no thermal degrada-tion.
· Automatic liquid injection sup-ported directly onto columns ≥0.250mm id.
· Maximum temperature:450ºC . Temperature programming in 3 ramps or tracking oven. Subambient control to-40ºCis optional.
· Electronic pressure control range:0 to 100 psig. · Electronic septum purge flow control.
Optional solvent vapor exit for large-volume injections.
-Electronically controlled,inert, three-way valve allows solvent venting.
-Preassembled retention gaps/vent line/analytical column for easy installation.





VI
Very low volume ( 32 μL) interface suitable for gas or prevaporized samples. Recommended for use with headspace,purge and trap,or thermal desorption samplers. Three modes for optimized sample introduction: split (up to 100:1 split ratio),splitless,and direct. Optimized EPC (H or He carrier, 0.00 to 100 psig pressure control, 0.0 to 100 mL/min flow
control). · Electronic septum purge flow con-trol.
Treated flow path provides inert sur-face for minimum
 
  component adsorption.
Maximum temperature:400ºC .









FID Detector
Minimum detectable level (for tridecane): <2.1 pg="" c="">
Linear dynamic range: >107 (±10%). Digital data makes entire range available without range changes.
• Data rates up to 200 Hz accommodate peaks as narrow as 25 ms at half height.
Standard EPC for three gases:
- Air: 0 to 800 mL/min
- H2: 0 to 100 mL/min
- Makeup gas (N2 or He): 0 to
100 mL/min
• Available in two versions: capillary column optimized or adaptable for either packed or capillary columns.
Flame out detection and automatic reignition.
Grounded jet.
• 450 °C maximum operating temperature.










TCD Detector
• Minimum detectable level: 500 pg propane/mL with He carrier. (This value may be affected by laboratoryenvironment)
Linear dynamic range: >105 ±5%.
Unique fluidic switching design provides rapid stabilization from turn-on, low-drift performance.
Signal polarity can be run programmed for components having higher thermal conductivity than the carrier gas.
Maximum temperature: 400 °C.
• Standard EPC for 2 gases (He, H2, Ar, or N2 - matched to carrier gas type).
Makeup gas: 0 to 12 mL/min.
• Reference gas: 0 to 100 mL/min

FPD Detector
· Provide single-wavelength flame photometric detector(FPD), or dual-wavelengthflame photometric detector (DFPD) - a sensitive, spe-cific detector to
 
  sulfur- or phospho-rus-containing compounds. · MDL:<<>67.5fgP/s,<3.75pgs> · Dynamic range:>103S,104 P with methylparathion · Selectivity:106g S/g C.106g P/g C
· Data acquisition rate: up to 200 Hz · Standard EPC for three gases:
-Air:0to200mL/min -H:0to 250 mL/min -Makeup gas:0 to 130 mL/min · Available in single- or dual-wave-length versions.
· 400°C maximum operating temperature







Micro-ECD Detector
Minimum detectable level: <12 fg="">
Proprietary signal linearization Linear dynamic range: >5 × 104 with lindane.
Data acquisition rate: up to 50 Hz.
• Uses ß emission of <3.7e+8bq 63ni="" as="" the="" electr="">on source.
• Unique micro-cell design minimizes contamination and optimizes sensitivity.
400 °C maximum operating temperature.
• Standard EPC makeup gas types: argon/5% methane or nitrogen; 0 to 150 mL/min.
Dynamic range: >5 × 105 with lindane








Auxiliary EPC
GC2019 has one positions for EPC devices located on the back of the GC. If customer need more EPC devices, external box for those parts could be installed at the left side. The box can contain 3 detectors(FID, TCD, ECD), 2 Aux EPC models.
Aux: Three channels of pressure control
· EPC compensated for atmospheric pressure and temperature variation when connected to a user-defined capillary column Psig(gauge)and psia(absolute)pressure control
· Forward pressure regulated
· Maximum of 4 auxiliary EPC modules per GC
PCM: Pneumatics Control Module
 
  1 channels for operation EPC compensated for atmospheric pressure and temperature variation when connected to a user-defined capillary column:
-Pressure or flow control
-Psig(gauge)and psia(absolute)pressure control
-Forward pressure regulated Second channel:
-Pressure control
-Psig(gauge)and psia(absolute)pressure control
- Forward pressure or back pressure regulated
· PCM can be located in either/both
inlet EPC positions, and in either/both auxiliary positions on the left side external box of the GC
· Maximum of 3 PCMs per GC











Capillary Flow Technology
Capillary Flow Technology provides devices with reliable, leak-free, in-oven capillary connections to help analyze complex samples and provide gains in productivity. Devices feature:
· Photolithographic chemical milling for low dead volume flow pathways
· Diffusion bonding to form a single flow plate
· "Credit card" profile for fast thermal response
· Projection welded connections for leak-tight fittings · Deactivation of all internal surfaces in the sample path for inertness
All of the following purged Capillary Flow devices require one channel from an auxiliary EPC or PCM module. Purged capillary flow devices,such as the Deans switch,purged effluent split-ters, and purged ultimate unions, intro-duce an additional flow in the sample stream. For detectors that operate at low flow rates, like the MSD and TCD, some decrease in sensitivity will occur.

 
Certifications

ISO,CE,ROHS,VGS.

Our Advantages
  1. Caidao has a large number of world-class and Chinese first-line high-quality customer groups.
  2. Caidao is the only company with all-round layout of "precision micro optics" in China.
  3. Up to now, the company has applied for more than 40 patents and software works, and has successively obtained the qualifications of Jiangsu private technology enterprises, Jiangsu sci.&tec.small and medium enterprises, Kunshan sci.&tec.R & D center, Shandong University industry-university-research cooperation tech. center, Shanghai sci.&tec. graduate workstation, National high-tech enterprises and so on.
  4. "The sixth generation AMOLED flexible screen laser repair detection microscope" won the pre selection of the first set of equipment in Jiangsu Province. "10.5G line super travel measurement microscope" won the entrepreneur Angel award of Kunshan sci.&tec. Bureau. Due to "High resolution and high efficiency automatic macro micro detection equipment" project, Caidao is the only shortlisted enterprise in Jiangsu which is holded by  the short board equipment of the Ministry of industry and information technology.
  5. The core members of the team have more than 10 years of industrial experience in optical instrument and pan semiconductor industry.
  6. Caidao has hardware module R & D + software platform module R & D + terminal application comprehensive technical solution ability.(1)One of few domestic equipment companies which have the ability to design and manufacture a complete set of precision mechanisms including linear single or double drive, air floating drive, screw and belt drive.(2)One of few domestic companies that can manufacture high-precision with super large range mechanical structures of more than 130 inches.(3)Compared with the competitors, one of few companies which have own intellectual property control system and self-developed chip algorithm, and which can cover most of the main products.(4)With comprehensive optical application capabilities, we can simultaneously master machine vision application of camera lens optical combination, micro optics with microscope application such as gold image, infrared, fluorescence, and laser application of measurement and repair.


 
After Sales Service

The customer can send the engineer to our company to complete the inspection of the goods, as well as the installation and training lessons, but the Visa fee, round tickets, accommodation, eating, and the allowance will be on customer's side.
Or we will send the engineers to install and test the machines and have training lessons abroad, but the Visa fee, round tickets, accommodation, eating, and the allowance of 80USD per day per person will be on customer's side.

FAQ

Q1: What are you main products?
A1: Jiangsu Caidao Precision Instrument Co., Ltd. was at country-level HDA of Kunshan, and Caidao has become a national high-tech enterprise in high-end optical image measurement and various inspection instruments, CMM, and AOI automatic testing equipment research and development, production and sales services.
The products include: manual and automatic vision measuring machine, precision measuring microscope, customized and AOI instruments.
Any question about this machine or our factory , please contact us ,sincerely serve for you .

Q2: What's your guarantee or the warranty of the quality if we buy your machines?
A : We offer you high quality machines with one year guarantee . We will give you free spare parts in one year.

If during the warranty period, the quality or specification of the goods is found to be inconsistent with the contractual requirements, or if the goods are found to be defective (including potential defects or the use of unqualified materials, etc.), the buyer has the right to use the inspection documents issued by the statutory authority. During the warranty period of the goods, the buyer shall make a claim against the seller.

Q2: Where is your company located ?How can i visit there?
A2:Our factory is located in Kunshan, Suzhou City, Jiangsu Province, China.

You can fly to Shanghai Pudong International Airport and we are warmly welcome to visit us.(Provide pick-up service.)

Q3: How can l get some samples?
A3: We have no sample. We will send you more pictures and video about this machine,and welcome to visit our factory to see the machine running in the factory.


Q4: How about the quality of your products?
A4: Our company guarantees that the products provided are brand new, unused, with the latest design and suitable materials, and comply with the quality, specification and performance of the contract in all respects.

Q5: Do you provide customized service?
A5: We can design the machines according your requirements (our brand, OEM, ODM),at the same time we will give you our professional suggestion, as you know, we have been in this industry for many years.


Q6: Do you have any famous customers?
A6: We have many famous customers such as SUMSUNG, HKC, BOE, PANDA, SHARP and so on.

Q7: How can I install my machine when it arrives?
A7: The customer can send the engineer to our company to complete the inspection of the goods, as well as the installation and training lessons, but the Visa fee, round tickets, accommodation, eating, and the allowance will be on customer's side.

Or we will send the engineers to install and test the machines and have training lessons abroad, but the Visa fee, round tickets, accommodation, eating, and the allowance of 80USD per day per person will be on customer's side.

Q8:What's the delivery time?
A8: 15-60 days after the T/T deposit.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now